Mini Fully Auto Chemstry Analyzer Discrete/ random access,
STAT sample priority,
User friendly interface,
No Computer required,
Internal thermal printer,
81 cuvettes,
27 positions for sample and,
54 positions for reagent,
Liquid level detection,
Collision protection,
High pressure water flush interior the probe,
Carry-over<0.1%
Technical Specifications
System Function
Feature
Description
Category
Random access fully automatic chemistry analyser
Speed
120test/hour
Methodology
End point, Fixed Point, Kinetic
Reagent
Open System/ Closed System
Reagent Position
54
Sample Position
32
Minimum reaction volume
150
Carry over
£0.005%
Minimum reaction Volume
500ul
Principle
Colorimetric, Turbid metric
Testing mode
Regular mode(single & dual reagents), Fast mode (single reagents)
Sample mode
Random access , STAT sample Priority
Sample System
Sample Volume
2-30 ul, stp by 1ul
Sample Tray
32 positions
Probe
Sample/Reagent mixing probe
One Probe for sample and regent with liquid level detection, vertical and horizontal collision protection and reagent volume real time time monitoring function
Reagent
Reagent Volume
20-300ul, step by 1 ul
Reagent Disc
54 regent position
Reagent Bottles
8ml, 24ml
Reaction Tray
Reaction Cuvettes
81 cuvettes
semi-permanent rigid UV special Plastic Cuvettes
Reaction temperature
37±0.°C
Reaction Volume
150-500ul
Minimum reaction time
12 minutes
Heating
Metal Thermal stat For reaction disc
Measuring & Optic system
Lamp
LED Xenon Lamp, 2000Hours
Filter
FMSS (full sealed matrix spectrometric system)
Wavelength
340-670nm, 8 wavelength, 800nm Optional
Resolution
0.0001Abs
Linear range
0-3.8Abs
Accurate
0.5A: <±0.02Abs, 1.0A: <±0.04Abs
Stray Light
³4.5
Stability
<0.1Abs/hour
CV%
<1.5%
Half Band accurate
<±2nm
Detector
Photodiode detector array
Cooling way
Content water cooling
Cal& QC
Calibration mode
One Pou=int Lineararm Two point linear, Multi point Liner, Logit-4p, Logit5p, Spline, exponential, polynomial
Calibration curve
Calibration curve auto check
Qc rule
Westguard multi-rule, Cumulative sum check, twin plot
Qc curve
westgard multi-rule, cumulative sum check, twin plot
Out Of control
Automatic wrning for items out of control, data automatic record, automartic analysis.
Software
Operating curve
Wion CP, Win7/*Win10
Data storage
Deiced By Computer Hard disc Memory
LIS Interface
bi-lis interface
System monitor
Real time monitoring for sample disc, reagent disc, reaction disc, real time monitoring for QC Status. Ra; time Monitoring for reaction cuvettes status, lamp status and temperature. Real time monitoring for reagent volume. Reaction curve, Calibration curve and QC Curve Linear Range limitation, substrate exhaustion judgment fault recover, automatic print, antistatic
Other function
User Permission administration test panel function, calculated manual parameter programming, avoid cross contamination function sample and reagent blank auto calculation, automatic fault recover, automatic print, data static.
Computer hardware requirement
CPU 2.5GHz, Memory 4gb, hard disc 500G, Monitor wide screen, 19 inch
PC interface
Rs-232C USB interface
Printout
Print mode
Built in thermal printer external printer option
Multi default formats, self- defined formats
Working condition
Dimension
350mmX320mmX595mm
Power Supply
AC100-240V, 50/60Hz±1Hz, £350VA
Net weight
22kg
Optional Parts
Reagent/sample Barcode Reader Water Purification modular, PC , HP Laser Printer